Schneider napajanja


Prikazano: 1516 - 1530 od 5510

    Stanje: 0

    3VA2612-5HN32-0AA0

    262,855.53 din

    fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU660, LSIG, In=1000A display, meas., comm. function Ir=400...1000A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% gr.-fault prot., can be sw. off Ig=0.1...1 x In, tg=0.1 - 1.0s front bus connector offset No communication connection, No measurement function Motorized operating mechanism 220...250 V AC/DC incl. S21 spring energy store signaling switch With electr. and mech. calling Switch-on solenoid (CC) 220-240 V AC/DC incl. remote reset solenoid (RR) reset remotely 220 V AC/DC with 2nd auxiliary release UVR time-del Undervoltage 220-240 V AC/DC incl. ext. time-delay device With 1st auxiliary release, ST Shunt release 220-240 V AC/DC K50= Ready indicator RTC auxiliary switch as version 24 V DC digital signal K51 Auxiliary current switch AUX 4 CO as version 24 V DC digital signal K53= Tripped signaling switch S24 as version 24 V DC digital signal K54= Spring charge status indicator S21 auxiliary switch as version 24 V DC digital signal

    Stanje: 0

    fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU650, LSI, In=1250A display, meas., comm. function Ir=500...1250A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% straight bus connector extended No communication connection, No measurement function Motorized operating mechanism 220...250 V AC/DC incl. S21 spring energy store signaling switch With electr. and mech. calling Switch-on solenoid (CC) 220-240 V AC/DC without 2nd auxiliary release With 1st auxiliary release, ST Shunt release 220-240 V AC/DC

    Stanje: 0

    3VA2712-1AE05-4HA7

    Cena na upit

    fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU660, LSIG, In=1600A display, meas., comm. function Ir=640...1600A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% gr.-fault prot., can be sw. off Ig=0.1...1 x In, tg=0.1 - 1.0s front bus connector offset No communication connection, No measurement function Motorized operating mechanism 220...250 V AC/DC incl. S21 spring energy store signaling switch With electr. and mech. calling Switch-on solenoid (CC) 220-240 V AC/DC incl. remote reset solenoid (RR) reset remotely 220 V AC/DC without 2nd auxiliary release With 1st auxiliary release, ST Shunt release 220-240 V AC/DC K50= Ready indicator RTC auxiliary switch as version 24 V DC digital signal K51 Auxiliary current switch AUX 4 CO as version 24 V DC digital signal K53= Tripped signaling switch S24 as version 24 V DC digital signal K54= Spring charge status indicator S21 auxiliary switch as version 24 V DC digital signal

    Stanje: 0

    fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU660, LSIG, In=1600A display, meas., comm. function Ir=640...1600A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% gr.-fault prot., can be sw. off Ig=0.1...1 x In, tg=0.1 - 1.0s front bus connector offset No communication connection, No measurement function Motorized operating mechanism 220...250 V AC/DC incl. S21 spring energy store signaling switch With electr. and mech. calling Switch-on solenoid (CC) 220-240 V AC/DC incl. remote reset solenoid (RR) reset remotely 220 V AC/DC with 2nd auxiliary release UVR time-del Undervoltage 220-240 V AC/DC incl. ext. time-delay device With 1st auxiliary release, ST Shunt release 220-240 V AC/DC K50= Ready indicator RTC auxiliary switch as version 24 V DC digital signal K51 Auxiliary current switch AUX 4 CO as version 24 V DC digital signal K53= Tripped signaling switch S24 as version 24 V DC digital signal K54= Spring charge status indicator S21 auxiliary switch as version 24 V DC digital signal

    Stanje: 0

    fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU650, LSI, In=1600A display, meas., comm. function Ir=640...1600A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% front bus connector offset No communication connection, No measurement function Without additional alarm switch assembly With mechanical calling with 2nd auxiliary release UVR time-del Undervoltage 220-240 V AC/DC incl. ext. time-delay device without 1st auxiliary release K51 Auxiliary current switch AUX 4 CO as version 24 V DC digital signal K53= Tripped signaling switch S24 as version 24 V DC digital signal

    Stanje: 0

    Stanje: 0

    3VA4110-4ED34-0AA0

    19,258.72 din

    Stanje: 0

    3VA4110-5ED34-0AA0

    21,384.12 din

    Stanje: 0

    3VA4110-6ED34-0AA0

    23,509.52 din

    Stanje: 0

    3VA4112-5ED34-0AA0

    35,524.53 din

    Stanje: 0

    3VA4112-6ED34-0AA0

    38,907.82 din

    Stanje: 0

    3VA4120-4ED34-0AA0

    14,834.42 din

    Stanje: 0

    3VA4120-5ED34-0AA0

    16,482.69 din

    Stanje: 0

    3VA4120-6ED34-0AA0

    18,087.58 din

    Stanje: 0

    3VA4125-5ED34-0AA0

    16,482.69 din

    Poslednje pregledani proizvodi


Opšti uslovi

Opšti uslovi i pravila kupovine
na našem sajtu


Način plaćanja

Pouzećem ili unapred
saznajte više


Kako kupovati

Saznajte sve o načinu kupovine
u našoj online prodavnici