Balluff induktivni senzori


Prikazano: 1891 - 1905 od 6954

    Connecting cable Length 0.15 m, flat, for connection of basic unit, current measuring module, current/voltage measuring module, operator panel or extension modules via the system interface

    Stanje: 0

    3UF7934-0AA00-0

    1,649.55 din

    Digital monitoring relay for 3-phase voltage with N-conductor Phase sequence can be activated Phase failure 3 x 90 to 400 V 50 to 60 Hz AC Undervoltage and overvoltage 90-400 V Hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax screw terminal Successor product for 3UG3042-1BP50

    Stanje: 0

    3UG4616-1CR20

    16,386.30 din

    Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer spring-type connection system

    Stanje: 0

    3UG4622-2AW30

    11,759.58 din

    Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal

    Stanje: 0

    3UG4815-1AA40

    16,627.28 din

    Stanje: 0

    3UG5511-1BR20

    7,470.23 din

    monitoring relay phase failure, phase sequence and asymmetry monitoring 3x 160-690 V AC, 15-70 Hz 1 changeover contact screw terminal

    Stanje: 0

    3UG5512-1AR20

    7,229.25 din

    Stanje: 0

    3UG5512-1BR20

    8,337.74 din

    Stanje: 0

    3UG5514-1BR20

    10,410.12 din

    digitally adjustable monitoring relay phase failure, phase sequence, asymmetry, frequency, over- and under-voltage monitoring 3x 90-690 V AC, 15-70 Hz 2 changeover contacts screw terminal

    Stanje: 0

    3UG5616-1CR20

    14,072.94 din

    circuit breaker 3VA1 IEC Frame 160 breaking capacity class N Icu=25 kA @ 415 V 2-pole, line protection TM210, FTFM, In=100 A overload protection Ir=100 A permanently set short-circuit protection Ii=10 x In nut keeper kit

    Stanje: 0

    3VA1110-3ED22-0AA0

    14,747.67 din

    Stanje: 0

    3VA1110-3EF36-0AA0

    19,215.35 din

    Stanje: 0

    3VA1110-5ED36-0AA0

    21,037.12 din

    circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=100A without overload protection short-circuit protection Ii=7...16 x In nut keeper kit

    Stanje: 0

    3VA1110-6MH32-0AA0

    23,075.77 din

    circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected clamp connection

    Stanje: 0

    3VA1112-4EF46-0AA0

    42,334.49 din

    Stanje: 0

    3VA1112-5EE36-0AA0

    33,789.51 din

    Poslednje pregledani proizvodi


Opšti uslovi

Opšti uslovi i pravila kupovine
na našem sajtu


Način plaćanja

Pouzećem ili unapred
saznajte više


Kako kupovati

Saznajte sve o načinu kupovine
u našoj online prodavnici