Balluff konektori za senzore


Prikazano: 1471 - 1485 od 5510

    Stanje: 0

    3TY7693-0CM7

    48,154.84 din

    Basic unit SIMOCODE pro C, PROFIBUS DP interface 12 Mbit/s, RS 485, 4I/3O freely parameterizable, Us: 110...240 V AC/DC, input for thermistor connection Monostable relay outputs

    Stanje: 0

    3UF7000-1AU00-0

    43,587.56 din

    Basic unit SIMOCODE pro V PN GP , Ethernet/PROFINET IO, PN system redundancy, OPC UA server, Web server, transmission rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 Q freely parameterizable, Us: 24 V DC, input for thermistor connection Monostable relay outputs, expandable by 1 extension module(DM, TM, EM)

    Stanje: 0

    3UF7011-1AB00-1

    67,402.31 din

    Stanje: 0

    3UF7011-1AB00-2

    55,604.18 din

    Zastareo proizvod. Zamena 3UF79000AA010

    Stanje: 0

    3UF7900-0AA00-0

    Cena na upit

    Digital monitoring relay for 3-phase voltage with N-conductor Phase sequence can be activated Phase failure 3 x 90 to 400 V 50 to 60 Hz AC Undervoltage and overvoltage 90-400 V Hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax screw terminal Successor product for 3UG3042-1BP50

    Stanje: 0

    3UG4616-1CR20

    14,892.26 din

    Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer spring-type connection system

    Stanje: 0

    3UG4622-2AW30

    10,699.29 din

    Digital monitoring relay 3-phase supply voltage for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal

    Stanje: 0

    3UG4815-1AA40

    15,133.23 din

    Stanje: 0

    3UG5511-1BR20

    7,277.45 din

    digitally adjustable monitoring relay phase failure, phase sequence, asymmetry, frequency, over- and under-voltage monitoring 3x 90-690 V AC, 15-70 Hz 2 changeover contacts screw terminal

    Stanje: 0

    3UG5616-1CR20

    13,735.58 din

    circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, starter protection TM120M, AM, In=100A without overload protection short-circuit protection Ii=7...16 x In nut keeper kit

    Stanje: 0

    3VA1110-6MH32-0AA0

    22,511.88 din

    circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In N conductor unprotected clamp connection

    Stanje: 0

    3VA1112-4EF46-0AA0

    41,293.48 din

    Stanje: 0

    3VA1112-5EE36-0AA0

    32,965.38 din

    Stanje: 0

    3VA1116-1AA32-0AA0

    19,475.60 din

    circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=160A overload protection Ir=112A...160A short-circuit protection Ii=5...10 x In nut keeper kit

    Stanje: 0

    3VA1116-5EF32-0AA0

    38,907.82 din

    Poslednje pregledani proizvodi


Opšti uslovi

Opšti uslovi i pravila kupovine
na našem sajtu


Način plaćanja

Pouzećem ili unapred
saznajte više


Kako kupovati

Saznajte sve o načinu kupovine
u našoj online prodavnici