Prikazano: 1756 - 1770 od 6414
fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU660, LSIG, In=1600A display, meas., comm. function Ir=640...1600A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% gr.-fault prot., can be sw. off Ig=0.1...1 x In, tg=0.1 - 1.0s front bus connector offset No communication connection, No measurement function Motorized operating mechanism 220...250 V AC/DC incl. S21 spring energy store signaling switch With electr. and mech. calling Switch-on solenoid (CC) 220-240 V AC/DC incl. remote reset solenoid (RR) reset remotely 220 V AC/DC without 2nd auxiliary release With 1st auxiliary release, ST Shunt release 220-240 V AC/DC K50= Ready indicator RTC auxiliary switch as version 24 V DC digital signal K51 Auxiliary current switch AUX 4 CO as version 24 V DC digital signal K53= Tripped signaling switch S24 as version 24 V DC digital signal K54= Spring charge status indicator S21 auxiliary switch as version 24 V DC digital signal
3VA2716-1AF06-4MA7-Z K50+K51+K53+K54
fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU660, LSIG, In=1600A display, meas., comm. function Ir=640...1600A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% gr.-fault prot., can be sw. off Ig=0.1...1 x In, tg=0.1 - 1.0s front bus connector offset No communication connection, No measurement function Motorized operating mechanism 220...250 V AC/DC incl. S21 spring energy store signaling switch With electr. and mech. calling Switch-on solenoid (CC) 220-240 V AC/DC incl. remote reset solenoid (RR) reset remotely 220 V AC/DC with 2nd auxiliary release UVR time-del Undervoltage 220-240 V AC/DC incl. ext. time-delay device With 1st auxiliary release, ST Shunt release 220-240 V AC/DC K50= Ready indicator RTC auxiliary switch as version 24 V DC digital signal K51 Auxiliary current switch AUX 4 CO as version 24 V DC digital signal K53= Tripped signaling switch S24 as version 24 V DC digital signal K54= Spring charge status indicator S21 auxiliary switch as version 24 V DC digital signal
3VA2716-1AF06-4MP7-Z K50+K51+K53+K54
fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU650, LSI, In=1600A display, meas., comm. function Ir=640...1600A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% front bus connector offset No communication connection, No measurement function Without additional alarm switch assembly With mechanical calling with 2nd auxiliary release UVR time-del Undervoltage 220-240 V AC/DC incl. ext. time-delay device without 1st auxiliary release K51 Auxiliary current switch AUX 4 CO as version 24 V DC digital signal K53= Tripped signaling switch S24 as version 24 V DC digital signal
3VA2716-5AE06-0AP0-Z K51+K53
3VA4110-4ED34-0AA0
3VA4110-5ED34-0AA0
3VA4110-6ED34-0AA0
3VA4112-5ED34-0AA0
3VA4112-6ED34-0AA0
3VA4120-4ED34-0AA0
3VA4120-5ED34-0AA0
3VA4120-6ED34-0AA0
3VA4125-5ED34-0AA0
3VA4125-6ED34-0AA0
3VA4130-5ED34-0AA0